PUKYONG

화목보일러의 화재 위험성에 관한 연구

Metadata Downloads
Abstract
In this study, we conduct fire experiment using model of sandwich panels and plywood to analyze the problem of existing wood boiler's fire accident. also, as a result of field research of wood boiler using household, we can confirm the high fire hazard and the preferred fire-fighting facilities are fire extinguisher and selfcontained type fire alarm device by the survey. based on them, we suggest these resolution for the safe use of wood boiler.
As a result of three hours combustion experiment, the transmitted heat from chimney to sandwich panel wasn't progress to fire because of the sandwich panel's air bound.
After 2 hours 3 minutes combustion experiment, the flame of plywood which contacted with chimney was head to fire. At this moment, the temperature of chimney was measured 350 degree celsius. The heat transmitted from chimney to plywood progress to the fire because it doesn't radiate the heat but accrued.
Wood boiler’s connection of chimney and ceiling should be prevented fire from using incombustible material.
Keep selfcontained type fire alarm device and fire extinguisher around the wood boiler.
Wood boiler in current legal system didn't include to examination machine of the Energy Use Rationalization Act, not only refused the safety regulations for manufacturing step but also prevailed fraulent construction by unqualified person. Through revising related laws, we should provide users safety through revising related laws.
Author(s)
박경진
Issued Date
2016
Awarded Date
2016. 8
Type
Dissertation
Keyword
보일러 화목보일러 화재위험
Publisher
부경대학교 대학원
URI
https://repository.pknu.ac.kr:8443/handle/2021.oak/13435
http://pknu.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002298513
Affiliation
부경대학교 대학원
Department
대학원 소방공학과
Advisor
최재욱
Table Of Contents
1. 서 론 1
2. 이론적 배경 2
2-1. 보일러의 종류 2
2-2. 화목보일러의 구조와 작동원리 4
2-3. 화목보일러 화재발생 유형과 현황 6
2-3-1. 화재발생 유형 6
2-3-2. 화재발생 현황 8
2-3-3.인명피해 현황 10
2-4. 화목보일러 관련법 규정 12
2-5. 화목보일러 화재사례 조사 14
2-5-1. 주택 화재사례 조사(A) 14
2-5-2. 주택 화재사례 조사(B) 20
2-6. 소화 및 경보시설의 설치 필요성 25
3. 화재실험 및 현장평가 26
3-1. 실험목적 26
3-2. 실험장치 및 조건 27
3-3. 현장평가 29
3-3-1. 현장 실태조사 30
3-3-2. 설문조사 31
4. 결과 및 고찰 32
4-1. 샌드위치 패널의 화재실험 32
4-2. 합판의 화재실험 35
4-3. 현장평가 38
4-3-1. 현장 실태조사 결과 38
4-3-2. 설문조사 결과 40
5. 결 론 44
참 고 문 헌 46
Abstract 49
Degree
Master
Appears in Collections:
산업대학원 > 소방공학과
Authorize & License
  • Authorize공개
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.