負荷變化에 따른 3相 變壓器의 3次元 有限要素解析
- Alternative Title
- 부하변화에 따른 삼상 변압기의 삼차원 유한요소해석
- Abstract
- A transformer ideally changes one ac voltage level to
another voltage level without affecting the actual power
supplied. If a transformer steps up the voltage level of a
circuit, it must decrease the current to keep the power
into the device equal to the power out of it. Therefore, ac
electric power can be generated at one central location, its
voltage stepped up for transmission over long distances at
very low losses, and its voltage stepped down again for
final use. Because a transformer has series impedances
within it, the output voltage of a transformer varies with
the load even if the input voltage remains constant.
This paper describes on the characteristic analysis of 3
phase transformer according to load variation. The 3D
finite element analysis was used to find out the
characteristics of voltage, current and magnetic flux
density. It is shown that the magnitudes and the phases
secondary voltages and the magnetic flux densities were
unbalanced according to the load variation.
- Author(s)
- 최인석
- Issued Date
- 2017
- Awarded Date
- 2017. 2
- Type
- Dissertation
- Keyword
- 변압기 3상 유한요소해석 부하단자
- Publisher
- 부경대학교 산업대학원
- URI
- https://repository.pknu.ac.kr:8443/handle/2021.oak/13693
http://pknu.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000002331431
- Affiliation
- 부경대학교 산업대학원
- Department
- 산업대학원 전기공학과
- Advisor
- 박한석
- Table Of Contents
- 제 1 장 서 론 1
제 2 장 변압기 2
2.1 기본특성 2
2.2 이상적인 변압기 4
2.3 극성 판정 9
2.4 실제적인 변압기 11
2.5 전압 변동율 17
2.6 효율 20
2.7 3상 변압기 23
제 3 장 유한요소법 29
3.1 유한요소법 개요 29
3.2 유한요소해석 정식화 32
제 4 장 특성해석 결과 및 고찰 36
4.1 3상 변압기의 제원 36
4.2 특성 해석 결과 37
제 5 장 결 론 40
참고문헌 41
- Degree
- Master
-
Appears in Collections:
- 산업대학원 > 전기공학과
- Authorize & License
-
- Files in This Item:
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.