PUKYONG

진동형 히트파이프를 이용한 의류 건조기 배기열 회수 장치에 관한 연구

Metadata Downloads
Abstract
Currently, Usage of clothes dryers is increasing in worldwide because of reduction of sunshine and the busy life of modern people. In the United States, already in 2009, 80% of households use a clothes dryer. In the case of Korea, penetration rate has shown a growth rate of 2% per year and 10% of households use a clothes dryer. So high-efficiency clothes dryer is required. The biggest of energy loss in clothes dryer is heat of exhausted air after drying and it is 57% in total heat loss. It is useful to recover waste heat of exhausted air. In this study, we use pulsating heat pipe (PHP) for exhaust heat recovery system (EHRS) of clothes dryer to reduce energy consumption for air pre-heating before heat source.
Flat tube heat exchangers is used to PHP for EHRS of clothes dryer. and one of them is no fin in evaporator section in order to prevent contamination from condensate and lint of laundry. R-134a was used as working fluid
Three experiment was performed in this study. first experiment is to search for optimum charging ratio of working fluid in PHP with no fin in evaporator section. In experiment result, optimum charging ratio of working fluid is 40% of the total volume.
Second experiment is performance of PHP according to presence of the fin in evaporator section. Performance of PHP with all fin is higher than performance of PHP with no fin. And in the titration of fin pitch, it is possible to avoid to condensate and lint problem.
Lastly, third experiment is an experiment of PHP according to the number of inner flow channel of flat tube heat exchanger. In this experiment, performance of PHP was evaluated in difference of hydraulic diameters in same size of flat tube heat exchanger. One of the flat tube heat exchanger has 25 channels and hydraulic diameter is 1.02 mm. The other has 32 channels and hydraulic diameter is 0.84 mm. PHP of 25 channels with a large hydraulic diameter's performance was better than PHP of 32 channels's
Considering these results, It is possible to recovery and re-used the exhausted heat of clothes dryer using PHP.
Author(s)
구연우
Issued Date
2014
Awarded Date
2014. 2
Type
Dissertation
Publisher
부경대학교
URI
https://repository.pknu.ac.kr:8443/handle/2021.oak/1647
http://pknu.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001967056
Affiliation
대학원
Department
대학원 냉동공조공학과
Advisor
김종수
Table Of Contents
ABSTRACT Ⅰ
Nomenclature Ⅳ
List of Figures Ⅴ
List of Tables Ⅶ

제 1 장 서론 1
1.1 연구배경 1
1.2 연구목적 2

제 2 장 기초 이론 3
2.1 진동형 히트파이프 3
2.1.1 PHP 작동유체 선정 8
2.1.2 PHP의 안정작동을 위한 관경 상관식 14
2.2 의류건조기의 구조 16
2.3 선행연구 19
2.3.1 응축식 의류 건조기의 구조 19
2.3.2 히트파이프를 이용한 응축식 의류 건조기 21
2.1.1 PHP 형상에 따른 배기열 회수장치 성능 연구 23

제 3 장 실험 장치 및 방법 25
3.1 실험 장치 25
3.2 실험 장치의 구성 27
3.3 실험방법 30
3.3.1 증발부에 fin이 없는 PHP의 최적작동유체 충진률 31
3.3.2 증발부 fin의 유무에 따른 PHP의 성능 비교 실험 32
3.3.3 평판관 열교환기 내부유동채널 수에 따른 PHP의 성능 33

제 4 장 실험 결과 34
4.1 작동유체 충진률에 따른 증발부에 fin이 없는 PHP의 성능 34
4.2 증발부 fin의 유무에 따른 PHP의 성능 변화 38
4.3 평판관 열교환기 내부 유동 채널 수에 따른 PHP 성능 42

제 5 장 결론 46

참고 문헌 47