두 개의 입력을 가진 VCO를 이용하여 루프필터와 스퍼 크기를 줄인 위상고정루프
- Alternative Title
- A Loop Filter Size and Spur Reduced PLL with Two Input Voltage Controlled Oscillator
- Abstract
- A PLL was proposed that reduces the size of the loop filter while suppressing spur by using a VCO with two inputs. Through the stability analysis according to the operation state, the PLL is designed to operate stably after the phase fixing. It is a VCO that can reduce the size of the loop filter by increasing the effective capacitance of the capacitor through the simultaneous charge and discharge operation by two charge pumps and has two signals operating in opposite phases. The phase fixing time was set to 80s by using a LSI(Locking Status Indicator) indicating the phase locking state. The proposed PLL is designed using a supply voltage of 1.8V and a 0.18m CMOS process.
- Author(s)
- 문대현
- Issued Date
- 2019
- Awarded Date
- 2019. 2
- Type
- Dissertation
- Keyword
- 위상고정루프 전압제어발진기 전하펌프 루프필터 스퍼
- Publisher
- 부경대학교
- URI
- https://repository.pknu.ac.kr:8443/handle/2021.oak/23248
http://pknu.dcollection.net/common/orgView/200000183661
- Alternative Author(s)
- Dae Hyun Moon
- Affiliation
- 부경대학교 대학원
- Department
- 대학원 전자공학과
- Advisor
- 최영식
- Table Of Contents
- Ⅰ. 서론 1
Ⅱ. 위상고정루프의 기본 이론 3
2.1 위상고정루프의 구조 및 이론 3
2.2 기본 블록들의 동작특성 6
2.2.1 위상 검출기 6
2.2.2 전하펌프와 루프필터 9
2.2.3 전압 제어 발진기 11
2.2.4 주파수 분주기 11
2.3 전하펌프 위상 고정 루프의 선형적 분석 12
Ⅲ. 두 개의 입력을 가진 VCO를 이용하여 루프필터와 스퍼 크기를 줄인 위상고정루프 설계 17
3.1 제안한 위상고정루프의 구조 17
3.2 제안된 위상고정루프의 선형모델 해석 19
3.3 스퍼 감소 기술 23
3.4 패루프 전달 특성 25
3.5 회로 설계 27
3.5.1 위상-주파수 검출기 27
3.5.2 전하 펌프 29
3.5.3 전압제어 발진기 31
3.5.4 주파수 분주기 33
3.5.5 락킹 상태 표시기 34
Ⅳ. 시뮬레이션 결과 37
4.1 시뮬레이션 결과 37
Ⅴ. 결론 42
참고문헌 43
- Degree
- Master
-
Appears in Collections:
- 대학원 > 전자공학과
- Authorize & License
-
- Files in This Item:
-