반밀폐형 퓨즈의 차단용량 상승을 위한 Fe-Ni 합금 가용체의 형상 및 퓨즈링크 구조 설계
- Alternative Title
- Design of Fuse-Link Structure & Fe-Ni Alloy Element’s Shape to Increase an Interrupt Rating of a Semi-Enclosed Type Fuse
- Abstract
- According to a miniaturization and integration of electric device, a little size of fuse satisfying the current carrying capacity as well as an explosive tolerance and current interrupt rating are required. Fe-Ni alloy is applied to decrease an oxidation of fuse elements. A resistance and T.C.R(temperature coefficient of resistance) of a fuse are analyzed by changing a content of Ni And full rated current I-T curve from 1A to 6.3A has been tested. In order to an explosive energy, a straight wire type is selected to reduce a fuse melting time.
An interrupt rating test was conducted by changing a content of Ni and the optimal content of Ni is to be 40%
- Author(s)
- 김성주
- Issued Date
- 2019
- Awarded Date
- 2019. 8
- Type
- Dissertation
- Keyword
- Fuse Interrupt rate Breaking capacity Semi-enclosed fuse Fuse-links
- Publisher
- 부경대학교
- URI
- https://repository.pknu.ac.kr:8443/handle/2021.oak/23550
http://pknu.dcollection.net/common/orgView/200000221373
- Affiliation
- 부경대학교 대학원
- Department
- 대학원 금속공학과
- Advisor
- 강창룡
- Table Of Contents
- Ⅰ 서론 1
1. 서 론 2
Ⅱ 이론적 배경 4
2. 퓨즈(Fuse) 5
2.1 연구 대상(퓨즈) 제품의 안전 기준 5
2.1.1) 관련 법률 5
2.1.2) (현) 안전 인증 기준 현황 9
2.1.3) 이차전지 기반 에너지 저장 시스템 보호소자의 인증 규격 14
2.2 퓨즈의 정의 17
2.2.1) 퓨즈의 정의 17
2.2.2) 퓨즈의 보호 특성 18
2.2.3) 퓨즈 가용체 동작 이론 18
2.3 퓨즈의 보호 방법 21
2.3.1) 한계 전류 동작형 퓨즈 21
2.3.2) 전류 감지 동작형 퓨즈 31
Ⅲ 실 험 방 법 38
3.1 연구 대상(퓨즈) 제품의 안전 기준 39
3.2 퓨즈링크 열 이동 및 재료설계 43
3.3 실험 방법 47
Ⅳ 결과 및 고찰 51
4. 실험결과 52
Ⅴ 결론 62
5. 결론 63
참고문헌 64
- Degree
- Master
-
Appears in Collections:
- 산업대학원 > 금속공학과
- Authorize & License
-
- Files in This Item:
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.