PUKYONG

Cascaded H-Bridge 멀티레벨 인버터의 신뢰성 향상을 위한 고장 허용 제어

Metadata Downloads
Alternative Title
Fault Tolerant Control for Enhancing the Reliability of Cascaded H-Bridge Multilevel Inverter
Abstract
In this paper, a novel fault-tolerant control method is proposed for three-phase Cascaded H-Bridge (CHB) inverters, based on overmodulation. Typically, conventional methods adjust the amplitude of reference signals, thereby restricting their performance to the linear modulation range. In contrast, the proposed method leverages overmodulation to extend this range. Additionally, being software-based, the proposed method eliminates the need for additional hardware efforts. The proposed method is verified through simulation and experiment considering a 7-level CHB converter.
Author(s)
김민솔
Issued Date
2024
Awarded Date
2024-02
Type
Dissertation
Keyword
Cascaded H-Bridge (CHB) inverter, reliability, fault-tolerance, neutral-shift, overmodularion
Publisher
국립부경대학교 대학원
URI
https://repository.pknu.ac.kr:8443/handle/2021.oak/33560
http://pknu.dcollection.net/common/orgView/200000744353
Alternative Author(s)
kimminsol
Affiliation
국립부경대학교 대학원
Department
대학원 전기공학과
Advisor
고영종
Table Of Contents
제 1 장 서 론 1
1.1 연구 배경 1
1.1.1 멀티레벨 전력변환장치의 고장 허용 제어 3
1.2 연구의 목적 4

제 2 장 Cascaded H-Bridge (CHB) 멀티레벨 인버터의 구조 및 변조 기법 5
2.1 H-Bridge 인버터의 구조 및 변조 방법 5
2.2 Cascaded H-Bridge 멀티레벨 인버터 8

제 3 장 CHB 멀티레벨 인버터의 스위치 고장 허용 제어 12
3.1 CHB 멀티레벨 인버터의 선형변조영역 12
3.2 Bypass 회로 구성 및 스위칭 상태 15
3.3 기존의 소프트웨어 기반 허용 제어 기법 16
3.4 제안하는 허용 제어 기법 24
3.5 제안하는 허용제어 성능 분석 31

제 4 장 시뮬레이션 결과 36
4.1 회로도 및 파라미터 36
4.2 개루프(Open-loop) 제어 37
4.3 폐루프(Closed-loop) 제어 52

제 5 장 실험 결과 54
5.1 실험 구성 및 파라미터 54
5.2 실험 결과 56

제 6 장 결론 59
참고 문헌 61
감사의 글 64
Degree
Master
Appears in Collections:
대학원 > 전기공학과
Authorize & License
  • Authorize공개
  • Embargo2024-02-16
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.