PUKYONG

地下鐵 昇降場 制煙境界壁의 煙氣擴散 遲延에 대한 硏究

Metadata Downloads
Alternative Title
A study on delay in smoke spread of the Smoke Reservoir Screen in Subway Platform
Abstract
In this study, a fire with polyurethane has been assumed to see the suitability of the Smoke Reservoir Screen which is set up at the 17.4m *5.0m*7.0m size real platform. In order to analyze the effect of a fire to the evacuation stairway, temperature, carbon monoxide and flow speed at the evacuation stairway have been compared to each otherusing FDS(Fire Dynamics Simulator)program. According to this result, we’ve got the conclusion below.
1) The effect of ventilation speed was not too much different at the 1.2m/s and 2.27m/s ventilation speed without any relationship with Smoke Reservoir Screen set up
2) In case with Smoke Reservoir Screen set up, platform stairway and temperature of waiting room entrance was lower than the case without Smoke Reservoir Screen set up.
3) The density of carbon monoxide shows the similar result with temperature distribution.
4) In case without the Smoke Reservoir Screen set up, smoke moves fast to the stairway ceiling. On the other hands, in case with the Smoke Reservoir Screen set up, it was observed that the Smoke Reservoir Screen prevents the smoke diffusion through the investigation of temperature, a distribution of carbon monoxide, and the shape of smoke moving
5) From these result, it is concluded that the Smoke Reservoir Screen can provide more time for escaping
Author(s)
유삼열
Issued Date
2007
Awarded Date
2007. 8
Type
Dissertation
Keyword
FDS 제연경계벽 지배방정식 지하철 승강장
Publisher
부경대학교 산업대학원
URI
https://repository.pknu.ac.kr:8443/handle/2021.oak/3912
http://pknu.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001953880
Alternative Author(s)
Yoo, Sam-Yeal
Affiliation
부경대학교 산업대학원
Department
산업대학원 안전공학과
Advisor
박외철
Table Of Contents
1. 서론 = 1
1.1 연구 배경 = 1
1.2 연구 동향 및 목적 = 3
2. 수치모사 방법 = 7
2.1 지배방정식 = 7
2.2 계산방법 = 8
3. 분석 및 고찰 = 12
3.1 CASE Ⅰ = 12
3.2 CASE Ⅱ = 21
3.3 CASEⅠ CASEⅡ 유속 비교 = 30
3.4 CASE Ⅲ = 32
3.5 CASE Ⅳ = 41
3.6 CASEⅢ CASEⅣ 유속 비교 = 50
3.7 풍속에 따른 온도의 비교 = 52
3.8 제연경계벽에 따른 온도의 비교 = 58
4. 결론 = 64
참고문헌 = 65
Abstract = 66
Degree
Master
Appears in Collections:
산업대학원 > 안전공학과
Authorize & License
  • Authorize공개
Files in This Item:

Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.