버블젯 루프 히트파이프를 이용한 증발기 제상에 관한 연구
- Alternative Title
- Study for defrost of evaporator using Bubble Jet Loop Heat Pipe as a defrost device
- Abstract
- One of the problems in a refrigerator operation is the frost formation on a cold surface of the heat exchanger. The frost layer is formed when the water vapor meet cold fin & tube which lower than freezing point. This frost layer is usually formed in evaporators and the frost layer on the surface of a heat exchanger will make side effect such as thermal resistance, air volume, fan motor performance and so on. However, This important factor needs to be studied and improved.
This study shows a comparison between conventional electric heater and Bubble Jet Loop Heat Pipe as a defrost device in evaporator. They are compared in 4 factors of Evaporator temperature, Air temperature in the chamber, Heater temperature, Electricity consumption. The evaporator applied Bubble Jet Loop Heat Pipe shows low temperature variations in evaporator and air temperature in the chamber and low electricity consumption.
- Author(s)
- 황종호
- Issued Date
- 2011
- Awarded Date
- 2011. 2
- Type
- Dissertation
- Publisher
- 부경대학교
- URI
- https://repository.pknu.ac.kr:8443/handle/2021.oak/9700
http://pknu.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001963957
- Department
- 대학원 냉동공조공학과
- Advisor
- 김종수
- Table Of Contents
- 1. 서론 1
1.1 연구목적 및 배경 1
1.2 관련 연구 및 종래 연구 4
2. BJLHP의 개요 및 특성 6
2.1 BJLHP의 원리 6
2.2 작동 유체의선정 8
3. 실험장치 및 방법 15
3.1 실험 장치 15
3.2 실험 방법 및 조건 25
4. 실험 결과 및 고찰 27
4.1 제상시 히터의 온도 변화 27
4.2 증발기의 온도 변화. 30
4.3 챔버 내의 온도 변화 36
4.4 전력 소모량은 비교. 39
4.5 제상량 비교 40
5. 결론 41
참고 문헌 42
謝 辭 44
- Degree
- Master
-
Appears in Collections:
- 대학원 > 냉동공조공학과
- Authorize & License
-
- Files in This Item:
-
Items in Repository are protected by copyright, with all rights reserved, unless otherwise indicated.