유연성 탄소나노튜브 센서 기반의 구조물 건전성 감시를 위한 스트레인 발생 위치 추정 시스템
- Alternative Title
- A Strain Positioning System using Carbonnanotube Flexible Sensors For Structural Health Monitoring
- Abstract
- In this study, a carbon nanotube (CNT) flexible strain sensor (CFSS) was fabricated with CNT based rubber composite for the strain sensing of structural health monitoring (SHM). The CFSS is a biomimetic flexible continuous strain sensor by means of piezoresistivity in CNT/EPDM (Ethylene Propylene Diene M-class) composite. For the application of the CFSS of SHM, an artificial neuron network system (ANS) was developed using an array of CFSS for a signal processing system of the sensor and applied to a flexible membrane. Moreover, a strain positioning algorithm (SPA) was developed to find the localized strain information of ANS in Labview environments.
- Author(s)
- 김진호
- Issued Date
- 2011
- Awarded Date
- 2011. 2
- Type
- Dissertation
- Publisher
- 부경대학교
- URI
- https://repository.pknu.ac.kr:8443/handle/2021.oak/9794
http://pknu.dcollection.net/jsp/common/DcLoOrgPer.jsp?sItemId=000001964052
- Affiliation
- 부경대학교 일반대학원
- Department
- 대학원 메카트로닉스공학과
- Advisor
- 강인필
- Table Of Contents
- Ⅰ. 서 론 1
1. 연구배경 1
2. 연구목적 및 내용 3
Ⅱ. CFSS 제작 및 특성 4
1. CFSS 제작 4
2. CFSS 특성 파악 실험 5
2.1 CFSS의 정확성 5
2.2 CFSS의 감도 8
2.3 CFSS의 선형성 10
2.4 CFSS의 히스테리시스 13
2.5 CFSS의 반복성 15
2.6 CFSS의 제로드리프트 16
2.7 CFSS의 온도특성 19
2.8 CFSS의 응답특성 22
2.9 CFSS의 동적특성 23
Ⅲ. ANS 개발 24
1. ANS 정의 및 필요성 24
2. ANS 제작 24
2.1 CFSS를 이용한 33 Array 형태의 인공 신경망 제작 24
2.2 인공신경망의 신호처리 회로 구성 28
3. ANS에 가해진 외력의 위치 추정 알고리즘 SPA 개발 40
3.1 SPA 정의 및 필요성 40
3.2 CFSS의 특성을 이용한 SPA 설계 40
3.3 Labview 기반의 ANS에 가해진 외력의 위치 추정 시스템 46
Ⅳ. 결론 56